11400 Watt Dual Fuel Inverter Generator with Remote Start, Quiet Portable Generator for Whole House Backup, RV & Jobsite-GXS11400iRDC
SKU: GXS11400iRDC
UPC: 850055834392
- EPA, CARB 2023, UL2201, CSA
- ANSI/PGMA G300 Compliant with CO Sensor Shutdown
- Light Weight Technology: As Low as 205.0 lbs
- Load Sense Technology: Improves Fuel Efficiency and Reduces Air and Noise Pollution
- A-iPower Dual Fuel Generator Offers the Choice of Operating with Gasoline or Propane or Both with Fuel Sense Technology
- 8.5 Gallon Tank, up to 16.5 Hour Runtime
- 100 lbs. Propane Cylinder, up to 41.0 Hour Runtime
- Extended 56.5 Hour Runtime (No Refueling) with Fuel Sense Technology
- High Performance 459cc Engine
- Pure Sine Wave with <3% THD with All Copper Alternator
- Parallel Capable*: Double the Output
- As Low as 67dB Noise Level
- Multi-Featured Data Center
- Illuminated Control Panel
- Free Shipping
- Free Returns Within 30 days
Couldn't load pickup availability
Fuel Sense™ Technology
Fuel Sense™ Technology
Power Without Interruption
Automatically switches from propane to gasoline to keep the power on when propane is depleted or disconnected.
✔ Seamless fuel transition
✔ Longer runtime
✔ Continuous power
✔ Worry-free operation
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
11400 Watt Dual Fuel Inverter Generator with Remote Start, Quiet Portable Generator for Whole House Backup, RV & Jobsite-GXS11400iRDC
Description:
The A-iPower GXS11400RDC 11400-Watt Gasoline Inverter Generator has a high-performance 459cc engine, is ANSI/PGMA G300 compliant, and has an automatic CO Sensor shutdown. Featuring lightweight technology, the unit can weigh as little as 205 pounds, while its load sense technology improves fuel efficiency and reduces air and noise pollution.
This product offers the choice of operating the unit with gasoline, propane, or both, as it includes A-iPower’s Fuel Sense Technology. The 8.5-gallon gas tank provides up to 16.5 hours of runtime, while the 100-pound propane cylinder offers up to 41 hours of runtime, a combined 56.5 hours of operation with no refueling.
Featuring Pure Sine Wave with <3% THD and an all-copper alternator, the unit is parallel capable, using the Parallel Kit PK12000 (sold separately), offering double the output. The unit operates at as low as 67 decibels, plus it has a multi-featured data center and an illuminated control panel.
| SPECIFICATIONS | |
|---|---|
| Model Number | GXS11400iRDC |
| OUTPUT | |
| Starting / Running Watts (Gas) | 11400 / 9100W |
| Starting / Running Watts (Propane) | 10100 / 8100W |
| AC Voltage | 120/240V |
| Total Harmonic Distortion (THD) | <3% |
| Noise Level (dB) | As Low As 67 |
| ENGINE | |
| Starting System | Recoil / Electric Start / Remote | Fuel Type | Gasoline / Propane |
| Alternator Type | Permanent Magnet |
| Full Copper Alternator | Yes |
| Tank (Gas) | 8.5 Gal / 32.1 L |
| Runtime @ 25% Load (Gas) | Up to 16.5 Hour |
| Runtime @ 25% Load (Propane 100lbs) | Up to 41.0 Hour - 100 lb Tank |
| Fuel Sense Runtime @ 25% Load (Gas + Propane) | Up to 57.5 Hour |
| TECHNOLOGY & FEATURES | |
| Fuel Sense Technology | Yes |
| Low Idle Technology | Yes |
| CO Sensor Shutdown | Yes |
| Wheel Kit | Yes |
| Parallel Capable | Yes |
| Data Center | Yes |
| Illuminated Control Panel | Yes |
| CERTIFICATIONS | |
|---|---|
| Certifications | EPA, CARB 2024, UL2201, PGMA, CSA |
| PACKAGING | |
| UPC | 850055834392 |
| Assembled Unit Weight (Net) | 199.5 lb / 90.4 kg |
| Packaged Weight (Gross) | 242.5 lb / 109.9 kg |
| Package Dimensions | 29.1 x 25.9 x 28.3 in / 740.0 x 660.0 x 720.0 mm |
| GENERAL | |
| Warranty | 3 Year Limited Warranty |
Unboxing & Operation Video
Video content is being prepared and will be updated soon.
Stay tuned for more exciting content!
Maintenance Video
Video content is being prepared and will be updated soon.
Stay tuned for more exciting content!
Safety Q&A
1、Where should I place the generator during operation?
Always operate the generator outdoors only. Keep it at least 20 feet (6 m) away from doors, windows, and vents, and at least 5 feet (1.5 m) away from any combustible materials. Place it on a dry, stable surface under a protective cover or canopy to shield it from the weather.
2、What should I know before refueling a generator?
Always turn off the generator and let it cool down completely before refueling.
Use clean, fresh fuel of the recommended grade.
Never refuel while the generator is running or hot, as this may cause fire or explosion.
3、Where should I safely store a generator when not in use?
Store the generator in a cool, dry, and well-ventilated location. Make sure the air vents are not blocked and that it is kept away from any flammable materials.
4、How do I safely transport a generator?
Before transporting, turn off the unit, drain the fuel tank, and disconnect the spark plug. Keep the generator upright during transport, ensure ventilation openings are not blocked, and avoid exposure to heat or moisture.
Setup/Startup
1、How do I connect the generator battery? (For models with electric start)
When you first receive the generator, the negative battery cable is usually disconnected to prevent discharge during storage.
- Locate the negative cable near the top or rear of the battery.
- Attach the loose end of the negative cable to the negative terminal post of the battery and tighten securely with a bolt.
- ⚠ Caution: Avoid touching both the battery terminal and the generator frame with tools or metal objects at the same time to prevent short circuits.
2、What type of engine oil should I use?
Initial use (break-in period): SAE 30, 10W-30, or 5W-30 mineral oil is recommended.
After break-in: You may use either mineral oil or full synthetic oil.
High temperatures (above 95°F / 35°C): 10W-40 is recommended.
3、What type of gasoline should I use?
Use unleaded gasoline with an octane rating of 87 or higher, and with ethanol content of no more than 10% (E10).
⚠ Tip: Lower ethanol content helps extend the life of the carburetor, fuel system, and seals.
4、How do I add fuel and check the oil for the first time?
Before the first startup, fill with the recommended engine oil.
Check the dipstick and ensure the oil level is within the marked range.
When adding oil or fuel, avoid spills, keep away from open flames, and use a dedicated oil/fuel container for safety.
5、How do I start the generator with recoil (pull) start? - Set the breaker and master control switch to OFF.
- Select the fuel type:
Gasoline: Open the gasoline valve → Turn the fuel selector to Gasoline.
Propane: Close the gasoline valve → Turn the fuel selector to Propane → Connect the propane tank and open the valve. - Switch the battery to ON (or “RUN” on some models).
- Pull the recoil cord: Pull slowly until resistance is felt, then pull sharply. Repeat if necessary until the engine starts
6、How do I use the electric start function?
Ensure the battery is properly connected and charged.
Set the fuel switch to the correct position.Turn the start switch to START.
Once the engine starts, release the switch and let it return to RUN/ON.
7、Does the generator need to warm up?
Yes. After starting, let the engine run idle for 1–3 minutes to allow the oil to circulate fully before applying a load.
8、How do I safely connect electrical loads?
Start the generator before connecting any appliances.
Connect higher-wattage devices first (e.g., refrigerator, air conditioner), then smaller devices.
Do not exceed the rated wattage capacity of the generator.
9、How do I start the generator in cold weather?
Use engine oil suitable for low temperatures (e.g., 5W-30).Place the generator in a warmer environment or use an engine block heater if available.Expect longer starting times in freezing conditions — this is normal.tent goes here.
Maintenance
1、How do I change the generator oil?
- Place the generator on a level surface.
- Locate the oil drain bolt at the bottom lip of the crankcase and place a container underneath.
- Use a 12mm wrench to remove the drain bolt and allow the oil to drain completely.
- Reinstall the bolt, remove the oil filler cap, and refill with oil until it reaches the thread level of the cap.
Tip: If the generator is on a flat surface, excess oil will naturally overflow before it is overfilled.
2、How do I drain fuel from the tank? - Turn the fuel valve to the OFF position.
- Place a container under the fuel 3. filter cup (below the valve).
- Remove the cup and turn the valve to ON to drain fuel completely.
Reinstall the fuel filter cup.
3、How should I prepare my generator for long-term storage?
Turn the circuit breaker OFF and run the generator for 3–5 minutes.
Switch the fuel valve to OFF and let the engine run until it shuts down.
Turn the engine/battery switch to OFF.
Drain remaining fuel from the tank and carburetor.
Remove the spark plug, add 2 tablespoons of 10W-30 oil into the cylinder, and pull the recoil starter a few times to lubricate.Reinstall the plug.
Disconnect and remove the battery, then maintain it with a trickle charger.
Store the generator in a cool, dry, and well-ventilated location.
4、How do I maintain the generator battery?
Generator batteries can lose charge within 3–6 months of storage.
Disconnect the battery when not in use.
Use a 12V SLA-compatible trickle charger to keep it charged.
Avoid exposing the battery to extreme heat or cold.
5、How often should I perform generator maintenance?
Before each use: Check fuel level, engine oil, and air filter. Every 50–100 hours of operation: Change engine oil, clean the spark plug, and service the air filter. Long-term storage: Drain fuel completely and store the generator properly.
6、Do I need to replace the air filter, and how often?
Yes. The air filter should be cleaned every 25 hours of use and replaced every 100–150 hours, or more often in dusty conditions.
7、When should I replace the spark plug?
Inspect the spark plug every 100 hours of operation. Replace it if it shows wear, buildup, or damage.
8、How do I prevent stale fuel from damaging the engine?
If the generator will not be used for more than 30 days, add a fuel stabilizer to fresh gasoline or drain the fuel system completely.
How to Contact Us for Further Assistance:
Phone Support: Connect directly with our knowledgeable customer service team at 855-888-3598 for immediate assistance.
Email Support: Send us an email with your inquiry, and our support team will respond promptly.
Live Chat: Use our real-time chat feature to get instant answers to your questions.
GXS11400iRDC Manual
GXS11400iRDC Spec Sheet
GXS11400iRDC Quick Start Guide
Your cart
(0)
Order note
Coupon
Product Comparison
| Description |
| Price |
| Type |
| Running Watts |
| Starting Watts |
| Run Time |
| Noise Level |
| Start Type |
| This A-iPower gasoline inverter generator has a high-performance 459cc engine, Pure Sine Wave with <3% THD, and an all-copper alternator. The unit is ANSI/PGMA G300 Compliant with CO Sensor shutdown and has load sense technology, which improves fuel efficiency and reduces air and noise pollution. This dual-fuel inverter generator offers the choice of operating with gasoline, propane, or both and has Fuel Sense Technology. With an 8.5-gallon fuel tank, the unit can run up to 16.5 hours, and up to 41 hours with a 100-pound propane cylinder, a total of 57.5 hours. The GXS11400iRDC is also parallel capable, allowing users to double the output. Operating a noise levels as low as 67 decibels, the unit has a multi-featured data center and an illuminated control panel. | Regular price
Sale price
$3,999.99 CAD
Regular price
Unit price
/per
| Dual Fuel Inverter Generator | 9100 | 11400 | 16.5 | 67 | Recoil, Electric, Remote |
Choose your option
Vendor: A-iPower
- Modern
- Eco-certified
- Warranty
Hurry up, only 19 items left in stock.
This A-iPower gasoline inverter generator has a high-performance 459cc engine, Pure Sine Wave with <3% THD, and an all-copper alternator. The unit is ANSI/PGMA G300 Compliant with CO Sensor shutdown and has load sense technology, which improves fuel efficiency and reduces air and noise pollution.
This dual-fuel inverter generator offers the choice of operating with gasoline, propane, or both and has Fuel Sense Technology. With an 8.5-gallon fuel tank, the unit can run up to 16.5 hours, and up to 41 hours with a 100-pound propane cylinder, a total of 57.5 hours. The GXS11400iRDC is also parallel capable, allowing users to double the output.
Operating a noise levels as low as 67 decibels, the unit has a multi-featured data center and an illuminated control panel.