13,000W Tri-Fuel Portable Inverter Generator – 10,500W Running, Gasoline/Propane/NG, 120/240V 50A, Remote & Electric Start
SKU: AIQ13000iRT
UPC: 810191314424
- Performance Series Engine: 550cc engine with Cast Iron Sleeve & Low Oil Shutdown for reliable long-lasting performance.
- High Output: 13,000 starting watts - 10,500 running watts on gasoline; 12,000 starting watts - 9,500 running watts on LPG; 10,500 starting watts - 8,400 running watts on CNG.
- Tri Fuel Capability: Runs on gasoline, propane/LPG, or natural gas (CNG) for maximum fuel flexibility during emergencies or outdoor use.
- Quiet Inverter Technology: Advanced inverter system delivers clean and stable power with less than 3% THD for sensitive electronics.
- Digital Data Center: Provides quick access to real-time operating information including voltage, frequency, power output, fuel level, and runtime.
- Extended Runtime: Large 7.9-gallon (30L) metal fuel tank with fuel gauge supports longer operation.
- Simple Starting: Equipped with recoil, electric, and remote start options for convenient operation.
- Portable Design: Built with heavy-duty wheels, integrated handle, and locking brake system for easy transportation.
- CO Safety Protection: Built-in CO WATCH-GUARD system monitors carbon monoxide levels and automatically shuts down when unsafe conditions are detected.
- Multiple Outlet Options: Includes 120/240V outlets, RV-ready connections, USB outlet, and parallel capability for versatile power applications.
- Free Shipping (Contiguous U.S. 47 States Only)
- Free Returns Within 30 days
Couldn't load pickup availability
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
13,000W Tri-Fuel Portable Inverter Generator – 10,500W Running, Gasoline/Propane/NG, 120/240V 50A, Remote & Electric Start
Description:
The A-iPower AIQ13000iRT is a powerful 13,000-watt tri-fuel portable inverter generator designed to provide flexible, reliable backup power for home, outdoor, and emergency applications. Powered by a 550cc single-cylinder 4-stroke OHV engine, it delivers up to 13,000 starting watts and 10,500 running watts on gasoline, with additional output capability on propane/LPG and natural gas.
With gasoline, propane/LPG, and natural gas fuel options, the AIQ13000iRT gives you the flexibility to choose the fuel source that best fits your needs. Its Digital Inverter technology provides regulated power with less than 3% THD, while the 120/240V 50A NEMA 14-50R outlet supports high-power electrical loads.
Remote, electric, and recoil starting options provide convenient operation, while Low Idle technology automatically reduces engine speed according to the connected load to help minimize fuel consumption and operating noise. CO WATCH-GUARD continuously monitors carbon monoxide levels around the generator and automatically shuts down the engine when increasing CO levels are detected.
Built for demanding portable power needs, the AIQ13000iRT combines high output, multi-fuel flexibility, inverter technology, and multiple starting options in one versatile generator.
| AIQ13000iRT SPECIFICATIONS | |
|---|---|
| Model | AIQ13000iRT |
| Fuel Type | Gasoline / LPG / Natural Gas |
| OUTPUT | |
| Gasoline Starting / Running Watts | 13,000 / 10,500W |
| LPG Starting / Running Watts | 12,000 / 9,500W |
| Natural Gas Starting / Running Watts | 10,500 / 8,400W |
| AC Voltage | 120/240V |
| Rated Frequency | 60Hz |
| Phase | Single Phase |
| Total Harmonic Distortion (THD) | <3% |
| Noise Level @ 25% Load (dBA @ 7m) | 66 |
| ENGINE | |
| Engine Type | 550cc Single Cylinder |
| Engine Model | SV550 |
| Starting System | Recoil / Electric / Remote Start |
| Low Oil Shutdown | Yes |
| Cast Iron Sleeve | Yes |
| Alternator Type | Permanent Magnet Inverter |
| Fuel Tank Capacity | 7.9 Gal / 30 L |
| Engine Speed (RPM) | 2600-3800 |
| CONTROL PANEL | |
| AC Outlets | NEMA 5-20R, L5-30R, TT-30R, L14-30R, NEMA 14-50R |
| DC Outlet | 12V DC Battery Charging Outlet |
| USB Outlet | Yes |
| Parallel Capability | Yes |
| Data Center | Voltage, Frequency, Power, Fuel Level, Runtime |
| Low Idle Mode | Yes |
| CO Monitor | CO WATCH-GUARD Automatic Shutdown |
| CERTIFICATIONS | |
|---|---|
| Certifications | EPA EXH / EPA EVAP / PGMA G300 / USDA Spark Arrester |
| TRANSPORTATION | |
| Wheel Type | 7" Flat-Free Wheels |
| Handle | Built-in Handle with U-Shape Handle Design |
| Brake System | Yes |
| PACKAGING | |
| Remote Control | Included |
| Battery | 18AH Battery Included |
| Battery Charger | Included |
| LPG Regulator | Included |
| Oil Bottle | 600ml × 2 |
| Net Weight | 282.2 lbs |
| Unit Dimension (L x W x H) | 36.6 x 30.9 x 28.3 in |
| Package Dimension | 32.9 x 27.0 x 31.5 in |
| Included Accessories | Remote Control, LPG Hose & Regulator, Battery Charger, Oil Funnel, Spark Plug Wrench, Tool Kit, Manual |
| GENERAL | |
| Warranty (Residential) | 3 Year Limited Warranty |
| Fuel Gauge | Yes |
| Fuel Tank Material | Metal |
| Frame Design | Fully Enclosed Metal Housing |
| Emergency Stop Switch | Yes |
Unboxing & Operation Video
Video content is being prepared and will be updated soon.
Stay tuned for more exciting content!
Maintenance Video
Video content is being prepared and will be updated soon.
Stay tuned for more exciting content!
Safety Q&A
1、Where should I place the generator during operation?
Always operate the generator outdoors only. Keep it at least 20 feet (6 m) away from doors, windows, and vents, and at least 5 feet (1.5 m) away from any combustible materials. Place it on a dry, stable surface under a protective cover or canopy to shield it from the weather.
2、What should I know before refueling a generator?
Always turn off the generator and let it cool down completely before refueling.
Use clean, fresh fuel of the recommended grade.
Never refuel while the generator is running or hot, as this may cause fire or explosion.
3、Where should I safely store a generator when not in use?
Store the generator in a cool, dry, and well-ventilated location. Make sure the air vents are not blocked and that it is kept away from any flammable materials.
4、How do I safely transport a generator?
Before transporting, turn off the unit, drain the fuel tank, and disconnect the spark plug. Keep the generator upright during transport, ensure ventilation openings are not blocked, and avoid exposure to heat or moisture.
Setup/Startup
1、How do I connect the generator battery? (For models with electric start)
When you first receive the generator, the negative battery cable is usually disconnected to prevent discharge during storage.
- Locate the negative cable near the top or rear of the battery.
- Attach the loose end of the negative cable to the negative terminal post of the battery and tighten securely with a bolt.
- ⚠ Caution: Avoid touching both the battery terminal and the generator frame with tools or metal objects at the same time to prevent short circuits.
2、What type of engine oil should I use?
Initial use (break-in period): SAE 30, 10W-30, or 5W-30 mineral oil is recommended.
After break-in: You may use either mineral oil or full synthetic oil.
High temperatures (above 95°F / 35°C): 10W-40 is recommended.
3、What type of gasoline should I use?
Use unleaded gasoline with an octane rating of 87 or higher, and with ethanol content of no more than 10% (E10).
⚠ Tip: Lower ethanol content helps extend the life of the carburetor, fuel system, and seals.
4、How do I add fuel and check the oil for the first time?
Before the first startup, fill with the recommended engine oil.
Check the dipstick and ensure the oil level is within the marked range.
When adding oil or fuel, avoid spills, keep away from open flames, and use a dedicated oil/fuel container for safety.
5、How do I start the generator with recoil (pull) start? - Set the breaker and master control switch to OFF.
- Select the fuel type:
Gasoline: Open the gasoline valve → Turn the fuel selector to Gasoline.
Propane: Close the gasoline valve → Turn the fuel selector to Propane → Connect the propane tank and open the valve. - Switch the battery to ON (or “RUN” on some models).
- Pull the recoil cord: Pull slowly until resistance is felt, then pull sharply. Repeat if necessary until the engine starts
6、How do I use the electric start function?
Ensure the battery is properly connected and charged.
Set the fuel switch to the correct position.Turn the start switch to START.
Once the engine starts, release the switch and let it return to RUN/ON.
7、Does the generator need to warm up?
Yes. After starting, let the engine run idle for 1–3 minutes to allow the oil to circulate fully before applying a load.
8、How do I safely connect electrical loads?
Start the generator before connecting any appliances.
Connect higher-wattage devices first (e.g., refrigerator, air conditioner), then smaller devices.
Do not exceed the rated wattage capacity of the generator.
9、How do I start the generator in cold weather?
Use engine oil suitable for low temperatures (e.g., 5W-30).Place the generator in a warmer environment or use an engine block heater if available.Expect longer starting times in freezing conditions — this is normal.tent goes here.
Maintenance
1、How do I change the generator oil?
- Place the generator on a level surface.
- Locate the oil drain bolt at the bottom lip of the crankcase and place a container underneath.
- Use a 12mm wrench to remove the drain bolt and allow the oil to drain completely.
- Reinstall the bolt, remove the oil filler cap, and refill with oil until it reaches the thread level of the cap.
Tip: If the generator is on a flat surface, excess oil will naturally overflow before it is overfilled.
2、How do I drain fuel from the tank? - Turn the fuel valve to the OFF position.
- Place a container under the fuel 3. filter cup (below the valve).
- Remove the cup and turn the valve to ON to drain fuel completely.
Reinstall the fuel filter cup.
3、How should I prepare my generator for long-term storage?
Turn the circuit breaker OFF and run the generator for 3–5 minutes.
Switch the fuel valve to OFF and let the engine run until it shuts down.
Turn the engine/battery switch to OFF.
Drain remaining fuel from the tank and carburetor.
Remove the spark plug, add 2 tablespoons of 10W-30 oil into the cylinder, and pull the recoil starter a few times to lubricate.Reinstall the plug.
Disconnect and remove the battery, then maintain it with a trickle charger.
Store the generator in a cool, dry, and well-ventilated location.
4、How do I maintain the generator battery?
Generator batteries can lose charge within 3–6 months of storage.
Disconnect the battery when not in use.
Use a 12V SLA-compatible trickle charger to keep it charged.
Avoid exposing the battery to extreme heat or cold.
5、How often should I perform generator maintenance?
Before each use: Check fuel level, engine oil, and air filter. Every 50–100 hours of operation: Change engine oil, clean the spark plug, and service the air filter. Long-term storage: Drain fuel completely and store the generator properly.
6、Do I need to replace the air filter, and how often?
Yes. The air filter should be cleaned every 25 hours of use and replaced every 100–150 hours, or more often in dusty conditions.
7、When should I replace the spark plug?
Inspect the spark plug every 100 hours of operation. Replace it if it shows wear, buildup, or damage.
8、How do I prevent stale fuel from damaging the engine?
If the generator will not be used for more than 30 days, add a fuel stabilizer to fresh gasoline or drain the fuel system completely.
How to Contact Us for Further Assistance:
Phone Support: Connect directly with our knowledgeable customer service team at 855-888-3598 for immediate assistance.
Email Support: Send us an email with your inquiry, and our support team will respond promptly.
Live Chat: Use our real-time chat feature to get instant answers to your questions.
AIQ13000iRT Manual
AIQ13000iRT Spec Sheet
AIQ13000iRT Quick Start Guide
Your cart
(0)
Order note
Coupon
Product Comparison
| Description |
| Price |
| Type |
| Running Watts |
| Starting Watts |
| Run Time |
| Noise Level |
| Start Type |
| The A-iPower AIQ13000iRT is a powerful 13,000-watt tri-fuel portable inverter generator designed to provide flexible, reliable backup power for home, outdoor, and emergency applications. Powered by a 550cc single-cylinder 4-stroke OHV engine, it delivers up to 13,000 starting watts and 10,500 running watts on gasoline, with additional output capability on propane/LPG and natural gas. With gasoline, propane/LPG, and natural gas fuel options, the AIQ13000iRT gives you the flexibility to choose the fuel source that best fits your needs. Its Digital Inverter technology provides regulated power with less than 3% THD, while the 120/240V 50A NEMA 14-50R outlet supports high-power electrical loads. Remote, electric, and recoil starting options provide convenient operation, while Low Idle technology automatically reduces engine speed according to the connected load to help minimize fuel consumption and operating noise. CO WATCH-GUARD continuously monitors carbon monoxide levels around the generator and automatically shuts down the engine when increasing CO levels are detected. Built for demanding portable power needs, the AIQ13000iRT combines high output, multi-fuel flexibility, inverter technology, and multiple starting options in one versatile generator. | Regular price
$2,699.00 USD
Sale price
Regular price
Unit price
/per
| Tri Fuel Generator | 10500 | 13000 | — | — | Recoil, Electric, Remote |
Choose your option
Vendor: A-iPower
Type: Tri Fuel Generator
The A-iPower AIQ13000iRT is a powerful 13,000-watt tri-fuel portable inverter generator designed to provide flexible, reliable backup power for home, outdoor, and emergency applications. Powered by a 550cc single-cylinder 4-stroke OHV engine, it delivers up to 13,000 starting watts and 10,500 running watts on gasoline, with additional output capability on propane/LPG and natural gas.
With gasoline, propane/LPG, and natural gas fuel options, the AIQ13000iRT gives you the flexibility to choose the fuel source that best fits your needs. Its Digital Inverter technology provides regulated power with less than 3% THD, while the 120/240V 50A NEMA 14-50R outlet supports high-power electrical loads.
Remote, electric, and recoil starting options provide convenient operation, while Low Idle technology automatically reduces engine speed according to the connected load to help minimize fuel consumption and operating noise. CO WATCH-GUARD continuously monitors carbon monoxide levels around the generator and automatically shuts down the engine when increasing CO levels are detected.
Built for demanding portable power needs, the AIQ13000iRT combines high output, multi-fuel flexibility, inverter technology, and multiple starting options in one versatile generator.
Special Offers (1)
First Order? Get 5% Off
Use promo code WELCOME5
- Choosing a selection results in a full page refresh.
- Opens in a new window.