AP10000ED - A-iPower 10000 Watt Dual Fuel Generator
SKU: AP10000ED
UPC: 850016881519
- Dual Fuel Power: 10,000 starting watts - 8,000 running watts on gasoline; 9,000 starting watts - 7,200 running watts on propane/LPG
- Engine: 420cc 4-stroke OHV engine constructed with a durable cast iron sleeve
- Fuel Tank: EXTRA LARGE 11.6 gal fuel tank provides up to 22.0 hrs. of run-time@25% load
- Weight: Weighs in at only 224.9 lbs.
- Sound Level: As low as 78 dBA operating volume
- VFT Data Center: Display with Voltage, Lifetime Hours and Frequency
- Outlet Configuration: 120V 5-20R GFCI duplex (2), 120V L5-30R, 120- 240V L14-30R, 12V multi-purpose outlet - USB ready
- Mobility: Hardened-steel frame with added roll bars, foam grip handle and flat-free wheels lets you easily transport this generator
- Unit Protection: Low oil shutdown
- Certification: EPA
- CO Sensor With Auto Shutdown: Monitors and reacts to carbon monoxide (CO) levels
Couldn't load pickup availability
Support documents and manuals remain available below.
AP10000ED - A-iPower 10000 Watt Dual Fuel Generator
Description:
The EPA-certified A-iPower AP10000ED inverter offers dual fuel power, with 10,000 starting watts and 8,000 running watts on gasoline and 9,000 starting watts and 7,200 running watts on propane/LPG. The 420cc 4-stroke OHV engine is constructed with a durable cast iron sleeve,and the unit features an extra large 11.6 gal fuel tank that provides up to 22 hours of run-time at 25% load.
Weighing only 224.9 pounds, the unit operates as low as 78 decibels, and its VFT Data Center displays voltage, lifetime hours, and frequency. The outlet configuration features a 120V 5-20R GFCI duplex (2), 120V L5-30R, 120-240V L14-30R, and 12V multi-purpose outlet, all USB ready.
The inverter has a hardened steel frame with added roll bars, a foam grip handle, and flat-free wheels that offer easy transport. The unit has a low oil shutdown as well as a CO Sensor that monitors and reacts to carbon monoxide (CO) levels, automatically shutting down if unsafe levels are reached.
| SPECIFICATIONS | |
|---|---|
| Model | GXS4300iDC |
| OUTPUT | |
| Starting/Running Watts (Gas) | 8000 / 10000W |
| Starting/Running Watts (LPG) | 7200 / 9000W |
| Voltage (V) | 120 / 240 |
| THD | Standard |
| Noise Level (dBA) | 78 |
| ENGINE | |
| Engine | 420cc / 4-stroke OHV engine |
| Starting System | Recoil Start / Electric Start - Battery Included |
| Alternator | Brushed |
| Oil Type / Capacity | SAE 10W-30 / 33.8 Oz - 1.05 Qt - 1.0 L |
| Tank Volume (Gal) | 11.6 |
| Runtime @ 25% Load (Hour) | 22.0 |
| CONTROL PANEL | |
| Outlets | GFCI 2x5-20R, 1xL5-30R, 1xL14-30R, 1x8.3A (12V DC) |
| Data Center | Multi-Meter: Displays voltage, frequency, running time. |
| CERTIFICATIONS | |
|---|---|
| Certifications | EPA |
| TRANSPORTATION | |
| Wheel Kit | U-type Handle - 9" Flat Free Wheel |
| PACKAGING | |
| UPC | 850016881519 |
| GENERAL | |
| Generator Overview | Electric / Recoil Start - Dual Fuel - 120/240V - Mobility Kit |
| Included Accessories | Oil Bottle (1000ml), Owner's Manual, Quick Start Guide, Tool Kit, Propane/LPG Hose with Regulator, Battery Charging Cable (12V DC), Mobility Kit, Battery |
| Warranty (Residential) | 2 Year Limited Warranty |
Unboxing & Operation Video
Video content is being prepared and will be updated soon.
Stay tuned for more exciting content!
Maintenance Video
Video content is being prepared and will be updated soon.
Stay tuned for more exciting content!
Safety Q&A
1、Where should I place the generator during operation?
Always operate the generator outdoors only. Keep it at least 20 feet (6 m) away from doors, windows, and vents, and at least 5 feet (1.5 m) away from any combustible materials. Place it on a dry, stable surface under a protective cover or canopy to shield it from the weather.
2、What should I know before refueling a generator?
Always turn off the generator and let it cool down completely before refueling.
Use clean, fresh fuel of the recommended grade.
Never refuel while the generator is running or hot, as this may cause fire or explosion.
3、Where should I safely store a generator when not in use?
Store the generator in a cool, dry, and well-ventilated location. Make sure the air vents are not blocked and that it is kept away from any flammable materials.
4、How do I safely transport a generator?
Before transporting, turn off the unit, drain the fuel tank, and disconnect the spark plug. Keep the generator upright during transport, ensure ventilation openings are not blocked, and avoid exposure to heat or moisture.
Setup/Startup
1、How do I connect the generator battery? (For models with electric start)
When you first receive the generator, the negative battery cable is usually disconnected to prevent discharge during storage.
- Locate the negative cable near the top or rear of the battery.
- Attach the loose end of the negative cable to the negative terminal post of the battery and tighten securely with a bolt.
- ⚠ Caution: Avoid touching both the battery terminal and the generator frame with tools or metal objects at the same time to prevent short circuits.
2、What type of engine oil should I use?
Initial use (break-in period): SAE 30, 10W-30, or 5W-30 mineral oil is recommended.
After break-in: You may use either mineral oil or full synthetic oil.
High temperatures (above 95°F / 35°C): 10W-40 is recommended.
3、What type of gasoline should I use?
Use unleaded gasoline with an octane rating of 87 or higher, and with ethanol content of no more than 10% (E10).
⚠ Tip: Lower ethanol content helps extend the life of the carburetor, fuel system, and seals.
4、How do I add fuel and check the oil for the first time?
Before the first startup, fill with the recommended engine oil.
Check the dipstick and ensure the oil level is within the marked range.
When adding oil or fuel, avoid spills, keep away from open flames, and use a dedicated oil/fuel container for safety.
5、How do I start the generator with recoil (pull) start? - Set the breaker and master control switch to OFF.
- Select the fuel type:
Gasoline: Open the gasoline valve → Turn the fuel selector to Gasoline.
Propane: Close the gasoline valve → Turn the fuel selector to Propane → Connect the propane tank and open the valve. - Switch the battery to ON (or “RUN” on some models).
- Pull the recoil cord: Pull slowly until resistance is felt, then pull sharply. Repeat if necessary until the engine starts
6、How do I use the electric start function?
Ensure the battery is properly connected and charged.
Set the fuel switch to the correct position.Turn the start switch to START.
Once the engine starts, release the switch and let it return to RUN/ON.
7、Does the generator need to warm up?
Yes. After starting, let the engine run idle for 1–3 minutes to allow the oil to circulate fully before applying a load.
8、How do I safely connect electrical loads?
Start the generator before connecting any appliances.
Connect higher-wattage devices first (e.g., refrigerator, air conditioner), then smaller devices.
Do not exceed the rated wattage capacity of the generator.
9、How do I start the generator in cold weather?
Use engine oil suitable for low temperatures (e.g., 5W-30).Place the generator in a warmer environment or use an engine block heater if available.Expect longer starting times in freezing conditions — this is normal.tent goes here.
Maintenance
1、How do I change the generator oil?
- Place the generator on a level surface.
- Locate the oil drain bolt at the bottom lip of the crankcase and place a container underneath.
- Use a 12mm wrench to remove the drain bolt and allow the oil to drain completely.
- Reinstall the bolt, remove the oil filler cap, and refill with oil until it reaches the thread level of the cap.
Tip: If the generator is on a flat surface, excess oil will naturally overflow before it is overfilled.
2、How do I drain fuel from the tank? - Turn the fuel valve to the OFF position.
- Place a container under the fuel 3. filter cup (below the valve).
- Remove the cup and turn the valve to ON to drain fuel completely.
Reinstall the fuel filter cup.
3、How should I prepare my generator for long-term storage?
Turn the circuit breaker OFF and run the generator for 3–5 minutes.
Switch the fuel valve to OFF and let the engine run until it shuts down.
Turn the engine/battery switch to OFF.
Drain remaining fuel from the tank and carburetor.
Remove the spark plug, add 2 tablespoons of 10W-30 oil into the cylinder, and pull the recoil starter a few times to lubricate.Reinstall the plug.
Disconnect and remove the battery, then maintain it with a trickle charger.
Store the generator in a cool, dry, and well-ventilated location.
4、How do I maintain the generator battery?
Generator batteries can lose charge within 3–6 months of storage.
Disconnect the battery when not in use.
Use a 12V SLA-compatible trickle charger to keep it charged.
Avoid exposing the battery to extreme heat or cold.
5、How often should I perform generator maintenance?
Before each use: Check fuel level, engine oil, and air filter. Every 50–100 hours of operation: Change engine oil, clean the spark plug, and service the air filter. Long-term storage: Drain fuel completely and store the generator properly.
6、Do I need to replace the air filter, and how often?
Yes. The air filter should be cleaned every 25 hours of use and replaced every 100–150 hours, or more often in dusty conditions.
7、When should I replace the spark plug?
Inspect the spark plug every 100 hours of operation. Replace it if it shows wear, buildup, or damage.
8、How do I prevent stale fuel from damaging the engine?
If the generator will not be used for more than 30 days, add a fuel stabilizer to fresh gasoline or drain the fuel system completely.
How to Contact Us for Further Assistance:
Phone Support: Connect directly with our knowledgeable customer service team at 855-888-3598 for immediate assistance.
Email Support: Send us an email with your inquiry, and our support team will respond promptly.
Live Chat: Use our real-time chat feature to get instant answers to your questions.
AP10000ED Manual
AP10000ED Spec Sheet
AP10000ED Quick Start Guide
-
-
-
-
-
No reviews found
No questions found
Please Wait ....
Your cart
(0)
Order note
Coupon
Product Comparison
| Description |
| Price |
| Type |
| Running Watts |
| Starting Watts |
| Run Time |
| Noise Level |
| Start Type |
| The EPA-certified A-iPower AP10000ED inverter offers dual fuel power, with 10,000 starting watts and 8,000 running watts on gasoline and 9,000 starting watts and 7,200 running watts on propane/LPG. The 420cc 4-stroke OHV engine is constructed with a durable cast iron sleeve,and the unit features an extra large 11.6 gal fuel tank that provides up to 22 hours of run-time at 25% load. Weighing only 224.9 pounds, the unit operates as low as 78 decibels, and its VFT Data Center displays voltage, lifetime hours, and frequency. The outlet configuration features a 120V 5-20R GFCI duplex (2), 120V L5-30R, 120-240V L14-30R, and 12V multi-purpose outlet, all USB ready. The inverter has a hardened steel frame with added roll bars, a foam grip handle, and flat-free wheels that offer easy transport. The unit has a low oil shutdown as well as a CO Sensor that monitors and reacts to carbon monoxide (CO) levels, automatically shutting down if unsafe levels are reached. | Regular price
$0.00 USD
Sale price
Regular price
Unit price
/per
| Dual Fuel Generator | 8000 | 10000 | 22 | 78 | Recoil |
Choose your option
Vendor: A-iPower
Type: Dual Fuel Generator
- Modern
- Eco-certified
- Warranty
Out of stock
The EPA-certified A-iPower AP10000ED inverter offers dual fuel power, with 10,000 starting watts and 8,000 running watts on gasoline and 9,000 starting watts and 7,200 running watts on propane/LPG. The 420cc 4-stroke OHV engine is constructed with a durable cast iron sleeve,and the unit features an extra large 11.6 gal fuel tank that provides up to 22 hours of run-time at 25% load.
Weighing only 224.9 pounds, the unit operates as low as 78 decibels, and its VFT Data Center displays voltage, lifetime hours, and frequency. The outlet configuration features a 120V 5-20R GFCI duplex (2), 120V L5-30R, 120-240V L14-30R, and 12V multi-purpose outlet, all USB ready.
The inverter has a hardened steel frame with added roll bars, a foam grip handle, and flat-free wheels that offer easy transport. The unit has a low oil shutdown as well as a CO Sensor that monitors and reacts to carbon monoxide (CO) levels, automatically shutting down if unsafe levels are reached.
- Choosing a selection results in a full page refresh.
- Opens in a new window.

